Corrugated 3/4" Metal Panel Installation Guide

S3 Metals 3/4" Tuff Rib panels provide a durable, economical exposed-fastener roofing and wall system with a traditional raised-rib profile. Designed for residential, commercial, and agricultural applications, these panels offer dependable performance and are supported by matching flashings, fasteners, closures, sealants, and accessories.

Introduction

S3 Metals™ is a locally operated metal roofing and panel supplier serving contractors, builders, property owners, and commercial and residential projects throughout Northern California. We supply 3/4" Tuff Rib metal roofing and wall panels, matching flashings, fasteners, closures, sealants, accessories, and custom-fabricated trim, with a focus on responsive service, accurate orders, and fast turnaround.


S3 Metals 3/4" Tuff Rib panels are designed for roof and wall applications requiring a durable, economical exposed-fastener metal panel system. The raised-rib profile provides a clean, traditional appearance suitable for residential homes, agricultural buildings, workshops, warehouses, and commercial structures. The system is supported by compatible ridge caps, valley flashing, eave trim, gable trim, sidewall and endwall flashing, closures, fasteners, and custom-fabricated accessories.


This installation guide provides general guidance for panel preparation, fastening, roof and wall flashing, panel overlaps, accessories, and common installation details. Project requirements may vary based on substrate conditions, drainage, wind exposure, climate, building design, local codes, and engineering requirements. S3 Metals supplies materials only and does not provide installation, supervision, engineering, field measurement verification, or project design. Responsibility for measurements, specifications, code compliance, safety, and installation remains with the appropriate project professionals and installer.


Thank you for considering S3 Metals.


David Hahne - Owner and Operator

DELIVERY & LOGISTICS

  • Handling of 3/4" Tuff Rib Panels

    S3 Metals™ is a locally operated metal roofing and panel supplier serving contractors, builders, property owners, and commercial and residential projects throughout Northern California. We supply 3/4" Tuff Rib metal roofing and wall panels, matching flashings, fasteners, closures, sealants, accessories, and custom-fabricated trim, with a focus on responsive service, accurate orders, and fast turnaround.


    S3 Metals 3/4" Tuff Rib panels are designed for roof and wall applications requiring a durable, economical exposed-fastener metal panel system. The raised-rib profile provides a clean, traditional appearance suitable for residential homes, agricultural buildings, workshops, warehouses, and commercial structures. The system is supported by compatible ridge caps, valley flashing, eave trim, gable trim, sidewall and endwall flashing, closures, fasteners, and custom-fabricated accessories.


    This installation guide provides general guidance for panel preparation, fastening, roof and wall flashing, panel overlaps, accessories, and common installation details. Project requirements may vary based on substrate conditions, drainage, wind exposure, climate, building design, local codes, and engineering requirements. S3 Metals supplies materials only and does not provide installation, supervision, engineering, field measurement verification, or project design. Responsibility for measurements, specifications, code compliance, safety, and installation remains with the appropriate project professionals and installer.


    Thank you for considering S3 Metals.

  • Material Storage for 3/4" Tuff Rib Panels

    Store all panels, flashings, and accessories in a dry, well-ventilated location on level ground. Elevate material bundles off the ground and provide adequate support to prevent sagging, distortion, and water accumulation. Slightly elevate one end of stored bundles to promote drainage.


    If materials must be covered, maintain adequate airflow around and beneath the bundles to prevent condensation and moisture buildup. Water trapped between stacked panels can cause staining, finish damage, and premature corrosion.


    If materials become wet during transportation or storage, immediately separate individual panels, wipe them dry with a clean cloth, and allow them to air dry completely before restacking.


    Remove protective plastic film from panels, trim, and flat sheets before installation. Avoid storing materials with protective film in direct sunlight, prolonged UV exposure, or extreme temperatures, as the film may become difficult to remove.


    Secure all materials stored on the ground or roof to prevent movement caused by wind. Unsecured materials can cause product damage, property damage, or personal injury.

  • Safety Statement

    Avoid handling or installing metal roofing materials during high-wind conditions. Long metal panels can be difficult to control, creating additional hazards during lifting, transportation, and installation.


    All handling, installation procedures, fall protection, and jobsite safety measures are the responsibility of the installer and appropriate project professionals.


    Follow applicable OSHA requirements, local safety regulations, and accepted industry practices. Use suitable fall protection, gloves, eye protection, hearing protection, and other required personal protective equipment.


    S3 Metals supplies roofing materials only and does not provide installation, jobsite supervision, or construction safety management.

  • Customer Responsibilities

    • Verify that adequate site access is available before delivery is scheduled.
    • Be present or arrange for an authorized representative to receive materials.
    • Provide unloading equipment, assistance, or labor as required.
    • Inspect all delivered panels, trim, flashings, and accessories.
    • Verify delivered quantities against the packing list.
    • Report shortages, visible damage, or material discrepancies to S3 Metals within 48 hours of delivery.
  • Delivery Information

    • Delivery schedules are typically confirmed one business day in advance.
    • S3 Metals will make every reasonable effort to deliver materials on time.
    • Delays caused by weather, traffic, road closures, equipment issues, or other factors beyond our control may occur.
    • Customers will be notified of significant delays whenever possible.
  • Site Access Requirements

    • Delivery locations must be reasonably accessible and safe.
    • Narrow roads, steep grades, tight turns, overhead obstructions, or unsafe site conditions may prevent direct delivery.
    • If necessary, materials may be delivered to an alternate location approved by the customer.
    • Additional delivery charges may apply for special accommodations, return trips, or failed delivery attempts.
  • Material Responsibility

    • Upon delivery or release of materials, responsibility transfers to the buyer.
    • Materials should be inspected, secured, and stored in accordance with S3 Metals handling and storage guidelines.

ROOF PREPARATION

Click to Reveal Instructions and Guidance:

  • Installation Tools

    • Variable-speed screw gun with adjustable clutch
    • Extra batteries and charger
    • Magnetic bit holder
    • #2 Square Drive or Phillips bits
    • 1/4" Magnetic Hex Driver
    • 1/8" Drill Bit
    • Tape Measure
    • Chalk Line
    • Marking Pen or Grease Pencil
    • Rivet Tool
  • Cutting Tools

    • Left and Right Offset Snips
    • Left and Right Aviation Snips
    • Electric Shears (recommended for long cuts)
  • Additional Tools

    • Deburring Tool
    • Hole Punch
    • Rubber Mallet
    • Framing Square or Speed Square
    • Duckbill Pliers or Vise Grips
    • Panel Upender Tools
    • Tool Belt or Holster
  • New Construction

    S3 Metals Snap-Lock roofing systems are designed for installation over a solid, continuous roof deck. A minimum 1/2" plywood or OSB substrate is recommended. Roof decking should be flat, secure, dry, and free of debris before installation begins. Install an approved roofing underlayment over the entire roof surface in accordance with local building codes and manufacturer specifications. Follow all underlayment overlap and fastening requirements to ensure proper moisture protection.

  • Re-Roof Applications

    Snap-Lock panels may be installed over a single layer of existing asphalt composition roofing were permitted by local building codes and where the existing roof surface is flat, secure, and in good condition.

  • Before Installation

    • Inspect the roof deck for damage, rot, or structural deficiencies.
    • Repair or replace damaged sheathing as necessary.
    • Remove loose materials, protruding fasteners, moss, and debris.
    • Verify compliance with local code requirements regarding roof overlays.
  • Roof Surface Considerations

    • Proper attic and roof ventilation are critical to long-term roof performance.
    • Follow all local building code ventilation requirements.
    • Ridge ventilation openings should be installed where applicable.
    • Use approved vent materials and insect screening.
    • Provide adequate airflow between insulation and roof decking.
    • Insufficient ventilation can contribute to moisture buildup, reduced roof life, and premature deterioration of materials.
  • Insulation:

    Insulation design should comply with local building codes and project-specific energy requirements. Consult the project's architect, engineer, or insulation professional when determining insulation specifications.

  • Touch-Up Paint

    • Minor scratches and handling marks should be repaired using manufacturer-approved touch-up paint.
    • Apply paint only to the affected area.
    • Use a fine brush or applicator rather than spraying directly onto the panel.
    • Excessive touch-up paint may create visible color variations over time.
    • Touch-up paint is intended for minor repairs and should not be used to repaint large panel surfaces.
  • Substrate Statement

    S3 Metals 3/4" Tuff Rib exposed-fastener panels may be installed over properly designed solid roof decking or spaced structural supports. Substrate type, support spacing, fastener selection, and attachment requirements must be verified based on project-specific engineering, applicable building codes, and approved construction details.

RECOMMENDED FASTENERS

Recommended Fastenters

  • Woodfast Screw #10

    pancake head screw used in metal roofing installation
    • #10 x 1", 1-1/2" 1/4" Hex Head
    • Color Matched

    #10 Woodfast screws are used to attach panel to dimensional lumber.

  • Woodfast Screw #14

    wafer head screw used in metal roofing installation
    • #14 x 1", 1-1/2" 5/16" Hex Head
    • Color Matched

    #14 Woodfast screws are used to attach the panel to plywood/OSB.

  • Stitch Screw

    Black-and-white illustration of a metal screw with a washer and hex nut

    #12 x 3/4" 1/4" Hex Head Color Matched


    Stitch Screws are used to attach metal to metal such as lap joints, trim to trim, trim to panel and side lap attachment. They can be used interchangeably with rivets.

  • Stitch Screw #12

    Black-and-white drawing of a screw with a hex head and washer-like top.

    Size: #12 × 3/4"

    Head: 1/4" Hex Head, Color Matched


    Used for metal-to-metal connections, including panel side laps, trim-to-trim connections, and trim-to-panel attachments. Use compatible fasteners and sealant where required by the approved installation details.

  • Tek Screw #12

    Bolt with washer and nut, shown as a simple black-and-white technical illustration.

    Size: #14 × 7/8"

    Head: 5/16" Hex Head


    Used for attaching panels to metal purlins where specified by the approved fastening requirements.

  • Tek Screw #14

    Bolt with washer and nut, shown as a simple black-and-white technical illustration.

    #14 x 7/8" 5/16" Hex Head


    Used to attach Tuff Rib panels to metal purlins. Select the appropriate screw length and drilling capacity for the supporting metal.

  • Stainless Steel Blind Rivets

    Silver dropper pipette icon with a pointed tip and bulb handle

    Size: 1/8" × 1/8"

    Finish: Color-matched or Unpainted


    Used for approved metal-to-metal connections, including certain trim-to-trim and trim-to-panel attachments. Rivets are not automatically interchangeable with stitch screws.

Fasteners for 3/4" Tuff rib

  • Fastener spacing and placement must follow the approved fastening schedule for S3 Metals 3/4" Tuff Rib panels, based on substrate conditions, wind loads, and project requirements.
  • Install panel fasteners along each rib and at each purlin according to the approved fastening pattern.
  • In high-wind applications, additional fasteners may be required at panel ends, edges, corners, and side laps. Follow project-specific engineering and applicable building codes.
  • Whenever possible, overlap panels away from the prevailing wind direction.
  • Install stitch screws at panel side laps according to the approved Tuff Rib fastening schedule. Use compatible fasteners and sealant where required.
  • For plywood roof decking, panel screws should penetrate through the underside of the plywood by at least 3/8".
  • For dimensional lumber, panel screws should penetrate the wood by at least 1".
  • Use fasteners with EPDM sealing washers for roof and wall applications.
  • Use a 2,000 RPM screw gun with a depth-sensing nosepiece to achieve proper washer compression and sealing.
  • Do not over-tighten or under-tighten fasteners. Follow the correct installation illustrations in the guide.
  • Do not use #9 Woodfast screws for attachment to plywood. The guide specifies #14 Woodfast screws for plywood attachment.
  • Remove metal shavings and drilling debris from the work area daily to prevent rust staining and damage to protective panel coatings.

3/4" Tuff Rib Panel Profile Chart

Cabin Ridge

VENTED RIDGE DETAIL

vented ridge details for corrugated panels

LT RIDGE DETAIL

vented ridge details for corrugated panels for corrugated panels

WV VALLEY DIAGRAM

WV Valley diagram for corrugated panels

EAVE DIAGRAM

eave details for corrugated panels

STEP EAVE DIAGRAMS

STEP EAVE DIAGRAMS for corrugated panels

GABLE DIAGRAMS

gable diagrams for corrugated panels

GABLE STEP DIAGRAMS

gable step diagram for corrugated panels

PEAK FLASHING FOR CORRUGATED PANELS

PEAK FLASHING FOR CORRUGATED PANELS

ENDWALL DIAGRAMS FOR CORRUGATED PANELS

ENDWALL DIAGRAMS FOR CORRUGATED PANELS

ALTERNATE ENDWALL DIAGRAM FOR CORRUGATED PANELS

ENDWALL DIAGRAMS FOR CORRUGATED PANELS

SIDE WALL DIAGRAMS FOR CORRUGATED PANELS

SIDE WALL DIAGRAMS FOR CORRUGATED PANELS

LAPPING APPLICATION DIAGRAMS

lapping application diagrams for corrugated panels

SHORT LAP APPLICATION

Short Lap Application for corrugated panels

LONG LAP APPLICATION

Long lap application for corrugated panels

WALL BASE & C-FLASHING FOR CORRUGATED PANELS

Wall Base and C-Flashings

INSIDE CORNER DIAGRAMS

inside corner diagrams corrugated panels

INSIDE POST CORNER DIAGRAMS

inside corner diagrams corrugated panels

OUTSIDE CORNER DIAGRAMS

Outside Corner Diagrams - Corrugated Panels

MINI CORNER DETAIL AND DIAGRAMS

mini corner detail and diagrams for corrugated panels

INSIDE PITCH CHANGE DIAGRAMS

Inside Pitch Change - Corrugated

OUTSIDE PITCH CHANGE DIAGRAMS

Outside Pitch Diagrams - Corrugated

SOFFIT RANGE DIAGRAMS

Soffit Range Diagrams - Corrugated

DOOR TRACK DIAGRAMS

Door Track Diagrams - Corrugated

PAN FLASHING DIAGRAMS

Pan Flashing Diagrams - Corrugated

PROW DIAGRAMS

Prow Diagrams - Corrugated

DOOR JAM DIAGRAMS

Door Jam Diagrams - Corrugated

Please complete the form, and we'll contact you within 24 hours to help guide you through your next project.

Person on a couch using a laptop for a video call in a bright living room

Get a Metal Roofing Consult

Contact us

Coordinated


We work with the homeowner first, or the contractor first, either way S3 provides the materials and cuts you need to install.

In-house


We never outsource anything! From materials to our fleet, packing, unpacking, cutting, and preparation.

As Promised


Our prices, delivery dates, and project times are carefully planned and executed to perfection.

FREE Downloads to help understand Metal Roofing Dubability

Value Description

Right-pointing black arrow icon on a white background

Value Description

Black right-pointing arrow icon on a white background

Value Description

Black right-pointing arrow icon on a white background

Value Description

Right-pointing black arrow icon on a white background

Our Latest News

best metal roof colors,best colors for metal roofs
By Will Schmidt • August 6, 2026
Learn how metal roof colors affect energy efficiency, cooling costs, curb appeal, resale value, and long-term performance.
standing seam vs exposed fastener metal roofing
By Will Schmidt • July 9, 2026
Compare standing seam vs exposed fastener metal roofing for California projects. Learn cost, pitch, solar, oil canning, coatings, wind, and maintenance.
custom‑cut metal panels, California metal roofing lead times, S3 Metals rapid turnaround
By Will Schmidt • May 21, 2026
Learn how typical metal‑panel lead times compare with S3 Metals’ rapid turnaround within northern CA for homeowners and contractors.
Blank white banner with a thin black strip at the top and bottom